Fluids, pumps, psychrometrics & plant rooms
Fluid Mechanics, HVAC & Refrigeration
0 of 265 stars · 0 of 53 lessons done · report card →
Formula pick
—
Rearranging
—
Setup & units
—
Answers
—
Fluid Statics & Flow Fundamentals
- L1StartReading the fluiddensity, specific gravity, pressure, head, flow★★★★★
- L2StartPressure under depthP = ρgh · and the metre-to-kilopascal bridge★★★★★
- L3StartContinuityQ = Av · and the diameter that has to be squared★★★★★
- L4StartThe two headsthe same motion, priced in kilopascals and in metres★★★★★
- L5StartBernoulli between two pointspressure, motion and height, trading along a streamline★★★★★
- L6StartReynolds and the regime2300 · the number that decides which physics applies★★★★★
- L7StartBuoyancythe fluid pushed aside, and who actually pays★★★★★
- ★StartThe Standpipethe boss · no calculator · depth to pressure to jet to duty★★★★★
Pipe Flow & Head Loss
- L9StartDarcy–Weisbachthe L/D lever, and the v² punishment★★★★★
- L10StartFinding fthe regime decides the relation — and 2300 is the border★★★★★
- L11StartHazen–Williamsthe C factor, and what an old main confesses★★★★★
- L12StartMinor lossestwo sets of books for the same elbow★★★★★
- L13StartValve coefficientsKv and Cv — a valve priced by what it passes★★★★★
- L14StartMetering the flowsqueeze the stream, then read the squeeze★★★★★
- L15StartPipe wall and surgewhat the wall holds, and what a slammed valve throws at it★★★★★
- L16StartWhat the pipe holdssystem volume — the cylinder, and the awkward one★★★★★
- ★StartThe Longest Runthe boss · no calculator · one line sized end to end★★★★★
Pumps, Fans & Affinity Laws
- L18StartTotal dynamic headeverything converts to metres before anything is added★★★★★
- L19StartWater powerP = ρgQH · the kilowatts that actually reach the liquid★★★★★
- L20StartShaft power and efficiencyefficiency divides on the way out to the coupling★★★★★
- L21StartNPSH availablethe suction-side margin above boiling — and what eats it★★★★★
- L22StartAffinity with speedlinear, squared, CUBED — one lever, three exponents★★★★★
- L23StartAffinity with impeller trimsame ladder, different lever — and the metal does not grow back★★★★★
- L24StartFan lawsthe same three exponents, in pascals and cubic metres per second★★★★★
- L25StartSpecific speedone number that names the shape of the impeller★★★★★
- ★StartThe Pump Roomthe boss · no calculator · head to kilowatts to a new speed★★★★★
Psychrometrics
- L27StartReading moist airthree thermometers, a percentage, and four pressures★★★★★
- L28StartThe saturation curvehow much water air can hold — an exponential, not a line★★★★★
- L29StartHumidity ratio and RHthe 0.62198, the dry-air denominator, and why W does not move★★★★★
- L30StartDew pointthe temperature a surface starts to sweat at, two ways★★★★★
- L31StartWet bulbthe sling psychrometer, and the temperature evaporation can reach★★★★★
- L32StartEnthalpy and specific volumeper kilogram of DRY air — and what altitude does to the trade rules★★★★★
- L33StartMixing airstreamsmass-weighted averages, and the ratio that is not RH★★★★★
- ★StartThe Air Handlerthe boss · no calculator · outdoor meets return, and the coil pays for it★★★★★
Air Systems & Hydronics
- L35StartThe three air rulessensible, latent, total — one airstream, three questions★★★★★
- L36StartSensible heat ratiosensible over TOTAL — the number that decides cool from clammy★★★★★
- L37StartDuct velocityflow over area — and the rectangle that pretends to be round★★★★★
- L38StartAir changes per hourroomfuls an hour · and the two sixties between them★★★★★
- L39StartThe 500 rule4.18 kW per litre per second per kelvin — and what glycol takes back★★★★★
- L40StartLoop hardwarethe water grows, the tank swallows it, the fill valve lifts it★★★★★
- L41StartEmitters off designthe 1.3 exponent · why low-temperature heat shrinks a radiator★★★★★
- L42StartSeasonal energydegree-days to kilowatt-hours to dollars★★★★★
- ★StartThe Balancing Reportthe boss · no calculator · duct traverse to boiler input, and a verdict★★★★★
Refrigeration, Boilers & Cooling Towers
- L44StartTons, EER and COPthree dialects, one machine — and 3.517 is not 3.412★★★★★
- L45StartkW per tonthe one figure of merit where lower is better★★★★★
- L46StartCOP from enthalpiesrefrigerating effect over compressor work, straight off the chart★★★★★
- L47StartSuperheat and subcoolingtwo thermometers, two pressures, two verdicts★★★★★
- L48StartRefrigerant mass flowṁ = Q̇ / Δh, asked every way round★★★★★
- L49StartCondenser dutythe tower carries the load PLUS the compressor★★★★★
- L50StartTower temperaturesrange is the plant's doing; approach is the tower's★★★★★
- L51StartTower water balanceevaporation, cycles, blowdown, makeup — in that order★★★★★
- L52StartBoiler horsepower9.81 kW apiece — and it is not a horsepower★★★★★
- ★StartThe Plant Room Finalthe boss · no calculator · chiller nameplate to tower bleed★★★★★
Nothing here is locked — the path recommends an order, and you study what you need. Progress lives in this browser (it survives cache clears, not “clear site data”); sign-in with permanent tracking is coming.