Q=4WH1.522W0.026Q = 4 \, W \, H^{1.522 \, W^{0.026}}

Enter your known values, leave one input blank, and solves for the missing one. Try different units for next level excitement!

Learning zone

Ralph Parshall reworked the Venturi flume at Colorado Agricultural College in the 1920s into a shape that measures open-channel flow without any moving parts and, crucially, passes sediment instead of collecting it — which is why it is the standard primary device on wastewater plant influent to this day. Flow is a function of a single upstream depth measured at the Ha point, two-thirds of the way along the converging section. The USBR general free-flow equation for throats of 1 to 8 ft is Q = 4WH^(1.522 W^0.026), so a 2 ft flume under 1.5 ft of head passes about 15.0 cfs, and a 1 ft flume under exactly 1 ft of head passes exactly 4 cfs. Smaller 3, 6 and 9 inch flumes have their own published constants and are not covered by this form.

The word FREE in the name is the one that gets people. A Parshall flume reads correctly only while the downstream water is low enough that a hydraulic jump forms in the throat; once submergence — the ratio of downstream to upstream head — exceeds about 70%, backwater reaches upstream and the single-head reading over-reads badly, sometimes by 30% or more. That is the classic cause of a plant that appears to treat more water than the city sells. Check the flume dimensions with a tape rather than trusting the drawing, verify that the floor is level and the walls are plumb, and confirm that the ultrasonic transducer is truly at Ha and reading from a properly set zero: an installation error in a flume is a permanent, systematic billing error.

Parshall Flume Free Flow
Q=4WH1.522W0.026Q = 4 \, W \, H^{1.522 \, W^{0.026}}
Where
  • QQ= Discharge through the flume
  • WW= Throat width
  • HH= Upstream head
Missing one of these? Work it out first, then come back