Total Totals Index (Miller)

Also known as total totals · TT index · Miller total totals · vertical totals plus cross totals · VT + CT · TT thunderstorm index · T850 + Td850 - 2 T500 · severe thunderstorm index 850 500 · total-totals index

TT=VT+CT=(T850−T500)+(Td,850−T500)TT = VT + CT = \left(T_{850} - T_{500}\right) + \left(T_{d,850} - T_{500}\right)
sig figs

Worked example: VT 26 and CT 18 (16 / 8 / −10 °C) → TT = 44. Press Try an example to run it live, then adjust anything.

Enter your known values, leave one input blank, and solves for the missing one. Tap a variable’s symbol to see what it means, with a typical value. Change any unit and the answer follows.

Where Total Totals Index (Miller) fits

Missing an input?
Learning zone

Total Totals Index (Miller) explained

T500T850Td,850VTCTTT

Instability plus moisture. The Total Totals index is worked out from three readings of a weather-balloon sounding to gauge the chance of thunderstorms and how severe they may be. It adds two parts. The vertical totals, VT=T850−T500VT = T_{850} - T_{500}, are the cooling between 850 and 500 hPa and measure how unstable the air is. The cross totals, CT=Td,850−T500CT = T_{d,850} - T_{500}, are the 850 hPa dew point less the 500 hPa temperature and add the moisture low down. Together, TT=VT+CT=T850+Td,850−2 T500TT = VT + CT = T_{850} + T_{d,850} - 2\,T_{500}.

Reading the answer. A vertical total of 26 or more is enough instability for thunderstorms, and 40 is the dry adiabat. A cross total above 18 is often needed for convection to start. The index itself is read in degrees: the National Weather Service reads below 50 as weak and above 55 as a strong signal of severe storms. A high value does nothing if a strong capping inversion holds the air down.

A worked case. The marks of 26 and 18 make a natural test: 16 °C at 850 hPa, a dew point of 8 °C and minus 10 °C at 500 hPa give VT 26, CT 18 and TT = 44. A warmer, moister low level under colder air aloft, 18, 12 and minus 16 °C, gives VT 34, CT 28 and TT = 62. Because the three readings enter as differences, the same 44 case in kelvins (289.15, 281.15 and 263.15 K) gives the same 44. The page also solves for T500T_{500}, T850T_{850} or Td,850T_{d,850} when the index is known.

Where it comes from. Miller's 1972 notes on severe-storm forecasting procedures (AWS Technical Report 200) and the National Weather Service glossary and Louisville pages define it. The K index is the companion, which adds the 700 hPa dew-point depression for the depth of the moist layer. The vertical totals are the lapse rate between 850 and 500 hPa times the depth of the layer, and the dew-point page gives a dew point from a temperature and a humidity when a station reports only those.

Total Totals Index (Miller) formula

TT=VT+CT=(T850−T500)+(Td,850−T500)TT = VT + CT = \left(T_{850} - T_{500}\right) + \left(T_{d,850} - T_{500}\right)
Where
  • TTTT= Total Totals index (C°)
  • T850T_{850}= Temperature at 850 hPa (°C)
  • Td,850T_{d,850}= Dew point at 850 hPa (°C)
  • T500T_{500}= Temperature at 500 hPa (°C)
Where this comes from
  • Miller, R. C. (1972). Notes on analysis and severe-storm forecasting procedures of the Air Force Global Weather Central. AWS Technical Report 200 (Rev.), Air Weather Service, USAF (US federal work).
  • NOAA National Weather Service, Glossary, "Total-Totals Index" (US federal work, public domain): the 850 mb temperature plus the 850 mb dew point, minus twice the 500 mb temperature. Read it
  • NOAA National Weather Service, Louisville, "Env Parameters and Indices" (US federal work, public domain): TT = VT + CT, with VT and CT defined. Read it
Revised 30 October 2026
Cite this page

formula.expert. (2026, October 30). Total Totals Index (Miller) Formula & Calculator. https://formula.expert/solvers/total-totals-index